Category:1046 Pipe Liner: Difference between revisions

From Engineering_Policy_Guide
Jump to navigation Jump to search
Smithk (talk | contribs)
m updated links
Smithk (talk | contribs)
m updated link
Line 3: Line 3:
|'''MGS Information'''
|'''MGS Information'''
|-
|-
|[http://www.modot.mo.gov/business/materials/pdf/mgs/MGSINDEX.pdf Current General Services Specifications (MGS) By Subject]  
|[https://www.modot.org/general-services-specifications-mgs-subject Current General Services Specifications (MGS) By Subject]  
|}
|}



Revision as of 06:50, 12 October 2018

MGS Information
Current General Services Specifications (MGS) By Subject


This article establishes procedures for inspecting, accepting and reporting of pipe liner. Refer to Sec 1046 for MoDOT’s specifications.

1046.1 Apparatus

(a) Rule with suitable graduations to accurately measure the material to be inspected.

1046.2 Procedure

Pipe liner is to be accepted for use on the basis of certification, identification marking and field inspection.

Manufacturers supplying polyethylene pipe liner in accordance with ASTM D 3350 cell classification 345464C, shall provide certification that their pipe liner meets the dimensional requirements of Table 1046.1. Those manufacturers that have submitted acceptable certification will be placed in EPG 1046.5 Qualified Manufacturers. If a pipe liner does not meet the requirements of Table 1046.1, the manufacturers may submit their pipe liner dimensions, reasonable justification as to why the product should be accepted, and all pertinent supporting documentation and calculations. Upon approval, the manufacturer will be placed on the qualified list.

Figure 1046, ASTM D 3350 cell classification 345464C Pipe Liner

Table 1046.1, ASTM D 3350 Cell Classification 345464C Pipe Liner

Nominal I.D. of PPPL, in. 1,2 Average O.D., in. 1 Average Profile Height (P.H.), in. 1 Average Profile Width (P.W.), in. 1 Minimum Waterway Wall (W.W.), in. Minimum Wall Thickness (W.T.), in.
10.000 11.200 0.600 0.740 0.070 0.060
12.000 13.470 0.740 0.920 0.080 0.070
13.500 15.360 0.930 1.160 0.090 0.080
15.000 16.850 0.930 1.160 0.090 0.080
18.000 20.240 1.120 1.400 0.110 0.100
21.000 23.650 1.330 1.660 0.130 0.110
24.000 27.060 1.530 1.910 0.140 0.120
27.000 30.340 1.720 2.150 0.160 0.140
30.000 33.820 1.910 2.390 0.180 0.150
36.000 40.650 2.330 2.910 0.210 0.180
40.000 45.200 2.600 3.250 0.230 0.200
42.000 47.470 2.740 3.420 0.240 0.210
1 These dimensions shall be determined by taking at least 3 measurements and averaging the results.
2 A tolerance of +/- 1 percent will be permitted on the nominal I.D. measurements.

1046.2.1 Manufacturer’s Certification

Prior to acceptance of pipe liner, the manufacturer shall submit a manufacturer’s certification stating that the material supplied conforms to all of the requirements of the specifications for the specific type of pipe liner provided.

1046.2.2 Identification Marking

Each pipe is to be clearly marked by the manufacturer and the marking is to contain the manufacturer’s name and the applicable ASTM designation.

1046.2.3 Field Inspection

Field inspection shall consist of reviewing the certification, checking the identification marking, checking dimensional requirements and randomly checking the length and workmanship.

1046.4 Report (Records)

Field inspection shall be recorded in SiteManager, as described in Sample Record General Information . The sample record shall include the brand name, manufacturer's name, size, and lengths. The sample record is to indicate acceptance or rejection. If the sample record indicates rejection, the reason for rejection shall be stated in the Free Form test.

If the sample record indicates acceptance, the basis of acceptance of the pipe liner shall be that the manufacturer’s certification and examination of the material indicates that the material conforms to all of the requirements of the specifications.

Completion of sample records for materials purchased under a MoDOT purchase order is to be as described in EPG 1101 Materials Purchased by a Department Purchase Order.

1046.5 Qualified Manufacturers and Brand Names of ASTM D 3350 Cell Classification 345464C HDPE Pipe Liner (1046PPLPET2.)

A qualified list of ASTM D 3350 cell classification 345464C pipe liner is shown in the Pipe Liner Qualified Listing, Table 2.

To become qualified, submit the required information in accordance with Sec 1046.2 and all supporting documentation to:

Construction and Materials
P.O. Box 270
Jefferson City, MO 65102.