1036.7 Laboratory Testing for Sec 1036: Difference between revisions
m →1036.7.1 Procedure: Per Bridge and CM, removed metric references and removed AASHTO's M42 and M53 since they are so rarely needed |
m →1036.7.2 Sample Record: Per CM, updated links to AS 3510 |
||
Line 28: | Line 28: | ||
==1036.7.2 Sample Record== | ==1036.7.2 Sample Record== | ||
The sample record shall be completed in SiteManager, as described in [http:// | The sample record shall be completed in SiteManager, as described in [http://contribute.modot.mo.gov/business/materials/pdf/vol_3/AS3510.pdf Automation Section 3510], and shall indicate acceptance, qualified acceptance, or rejection. Appropriate remarks, as described in [[106.20 Reporting|EPG 106.20 Reporting]], are to be included in the remarks to clarify conditions of acceptance or rejection. Test results shall be reported on the appropriate templates under the Tests tab. | ||
[[Category:1036 Reinforcing Steel for Concrete]] | [[Category:1036 Reinforcing Steel for Concrete]] |
Revision as of 06:29, 6 July 2011
This article establishes procedures for Laboratory testing and reporting samples of reinforcing steel for concrete. Refer to Sec 1036 for MoDOT's specifications.
1036.7.1 Procedure
Samples consist of uncoated and epoxy coated deformed bars, plain steel for fabric reinforcement. Original test results and calculations shall be reported through SiteManager.
1036.7.1.1 Billet-Steel Deformed Bars
Billet-steel deformed bars shall consist of Grade 40, 60 or 75 steel.
1036.7.1.1.1 Uncoated Billet-Steel
Samples of uncoated billet-steel deformed bars shall be tested in accordance with AASHTO M31. Tests consist of tensile properties, bending properties, weight variation, and measurements of deformations.
1036.7.1.1.2 Epoxy Coated Billet-Steel
Samples of epoxy coated billet-steel deformed bars, when submitted for steel properties, shall be tested in accordance with AASHTO M31 except that the weight (mass) variation and measurement of deformations shall not apply. The flexibility of coating test shall be performed in accordance with Sec 1036.
1036.7.1.2 Spiral Reinforcement
Spiral reinforcement shall conform either to the requirements for reinforcing steel bar, except that it may be plain or deformed; or it shall be cold drawn steel wire conforming to the requirements of AASHTO M32. Tests for plain steel bars are the same as for deformed bars except the requirements for deformations are not applicable. Tests for cold drawn steel wire consist of tensile properties, bending properties, and wire diameter variations.
1036.7.1.3 Welded Wire Fabric
Welded wire fabric shall be tested in accordance with AASHTO M55. Tests consist of tensile properties, bending properties, wire diameter variations and weld shear tests, if specified.
The wire diameter variations shall conform to the tolerances prescribed for the wire before fabrication in AASHTO M32 except that the manufacturer may use oversized wire in the fabrication of welded wire fabric, but not undersized wire. The size differential shall not exceed one "W" size increment on sizes W8 and smaller and two "W" size increments on sizes larger than W8. Sizes referred to are those shown in AASHTO M32. In all cases where oversizing exists, the fabric shall be identified and used as that originally ordered or offered for use.
1036.7.1.4 Samples Not Within Specifications
If a reinforcing steel sample is not within specifications on the initial sample and further testing is desired, resampling and testing should be done in accordance with the applicable specification for which the steel is being furnished. If no retesting procedures are indicated, random re-samples are to be double that initially taken from each lot sampled, and all resamples must comply with the specifications.
1036.7.2 Sample Record
The sample record shall be completed in SiteManager, as described in Automation Section 3510, and shall indicate acceptance, qualified acceptance, or rejection. Appropriate remarks, as described in EPG 106.20 Reporting, are to be included in the remarks to clarify conditions of acceptance or rejection. Test results shall be reported on the appropriate templates under the Tests tab.