Category:1005 Aggregate for Concrete: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
|||
Line 39: | Line 39: | ||
==1005.3 Records and Reports== | ==1005.3 Records and Reports== | ||
All plant records shown in [[:Category:1001 General Requirements for Material#1001.2.5 Records and Reports|General Requirements for Material - Records and Reports]] shall be maintained. The aggregates shall be reported through SiteManager in accordance with Automation Section AS-3510. | All plant records shown in [[:Category:1001 General Requirements for Material#1001.2.5 Records and Reports|General Requirements for Material - Records and Reports]] shall be maintained. The aggregates shall be reported through SiteManager in accordance with [[Automation Section AS-3510]]. |
Revision as of 08:55, 12 July 2007
This guidance establishes procedures for the inspection and acceptance of coarse and fine aggregate for use in concrete.
1005.1 Procedure
Inspection, testing, and sampling will be governed by the instructions contained in General Requirements for Material.
Field tests required are as follows:
TEST | Template | Template Description |
---|---|---|
Sieve Analysis | T27 | Sieve Analysis of Fine and Coarse Aggregate |
Percent Deleterious | SAA001Dx* | NEWEST Deleterious 1005 C Aggregate |
Lightweight particle content, including coal and lignite, in fine aggregate | SAA001Kx* | NEWEST Deleterious 1005 F Aggregate |
Absorption | SAA005Ax* | NEWEST Retained AASHTO T85 Absorption for Concrete Aggregate** |
SAA005Bx* | NEWEST Independent AASHTO T85 Absorption for Concrete Aggregate | |
Thin or Elongated Particles | SAA001Dx* | NEWEST Deleterious 1005 C Aggregate |
*Test Template numbers have been depicted with a generic ‘x’ as some templates are updated and the last letter in the template name may change. The most current template for a template sequence should contain ‘NEWEST’ at the beginning of the template name. | ||
**Test For Concrete Masonry accepted by the engineer, approximately 20% of retained samples will be sent to
the Central Lab for comparison purposes |
Samples required for Laboratory tests are as follows:
- (a) Initial Evaluation for coarse aggregate.
- (b) Source Approval.
- (c) Absorption as received and rodded unit weight (mass).
- (d) Source Approval for lightweight aggregate.
1005.2 Acceptance
Source Approval is based on the results of Laboratory tests. Acceptance is based on routine tests in the field to ensure compliance with Sec 1005.
1005.3 Records and Reports
All plant records shown in General Requirements for Material - Records and Reports shall be maintained. The aggregates shall be reported through SiteManager in accordance with Automation Section AS-3510.