Category:1059 Protective Coating Material: Difference between revisions
m →1059.2.1 Qualified Lists: updated links |
m Per CM, removed archaic SiteManager info and replaced with AASHTOWARE info |
||
Line 47: | Line 47: | ||
===1059.2.3 Sampling of Protective Coating for Concrete Bents and Piers (urethane), Protective Coating for Concrete Bents and Piers (epoxy), Concrete and Masonry Protective Systems, Sacrificial Graffiti Protection Systems and Temporary Coating for Concrete Bents and Piers (weathering steel)=== | ===1059.2.3 Sampling of Protective Coating for Concrete Bents and Piers (urethane), Protective Coating for Concrete Bents and Piers (epoxy), Concrete and Masonry Protective Systems, Sacrificial Graffiti Protection Systems and Temporary Coating for Concrete Bents and Piers (weathering steel)=== | ||
Take samples any time the certification indicates test results approaching the specification limits or any time that conditions warrant additional inspection. When samples are taken, the sample size is 1 qt. (1 liter) in a screw top can. Use | Take samples any time the certification indicates test results approaching the specification limits or any time that conditions warrant additional inspection. When samples are taken, the sample size is 1 qt. (1 liter) in a screw top can. Use AASHTOWARE Project (AWP) and include complete information as to brand name and lot or batch number. The manufacturer's certification for the lot sampled is retained in the district office. | ||
==1059.3 Report== | ==1059.3 Report== | ||
If the material is accepted in the field, it is reported through | If the material is accepted in the field, it is reported through AWP. The form should show all pertinent information regarding the material and the certification is retained in the district office. The report is to indicate acceptance, qualified acceptance, or rejection. Appropriate remarks, as described in [[106.20 Reporting|EPG 106.20 Reporting]], are to be included in the report to clarify conditions of acceptance or rejection. |
Latest revision as of 09:14, 18 October 2021
MGS Information |
Current General Services Specifications (MGS) By Subject |
This article establishes procedures for inspecting, accepting and reporting of protective coating for concrete bents and piers (urethane and epoxy), concrete and masonry protective systems, sacrificial graffiti protection system and temporary coating for concrete bents and piers (weathering steel). Refer to Sec 1059 for MoDOT’s specifications.
For Laboratory testing and sample reporting procedures, refer to EPG 1059.4 Laboratory Testing Guidelines for Sec 1059.
1059.1 Apparatus
Appropriate sampling thief and sample cans.
1059.2 Procedure
1059.2.1 Qualified Lists
Lists of qualified manufacturers and brand names of protective coating for concrete bents and piers (urethane and epoxy), concrete and masonry protective systems, sacrificial graffiti protection system and temporary coating for concrete bents and piers (weathering steel) is maintained by Construction and Materials. These lists are available at:
1059.2.2 Basis of Acceptance
1059.2.2.1 Acceptance of Protective Coating for Concrete Bents and Piers (urethane), Protective Coating for Concrete Bents and Piers (epoxy) and Temporary Coating for Concrete Bents and Piers (weathering steel)
Material on the list of qualified Protective Coating for Concrete Bents and Piers (urethane), Protective Coating for Concrete Bents and Piers (epoxy) and Temporary Coating for Concrete Bents and Piers (weathering steel) may be accepted on the basis of manufacturer's certification and random sampling and testing, when deemed necessary. The manufacturer's certification is to be furnished to the receiving district and is to certify that the material supplied is the same composition as originally qualified.
1059.2.2.2 Acceptance of Concrete and Masonry Protective Systems
Material on the list of qualified Concrete and Masonry Protective Systems may be accepted on the basis of manufacturer's certification and random sampling and testing, when deemed necessary. The manufacturer's certification is to be furnished to the receiving district and is to certify that the material supplied is the same composition as originally qualified. This material also requires field approval in accordance with Sec 1059.30.4.
1059.2.2.3 Acceptance of Sacrificial Graffiti Protection Systems
Material on the list of qualified Sacrificial Graffiti Protection Systems may be accepted on the basis of manufacturer's certification and random sampling and testing, when deemed necessary. The manufacturer's certification is to be furnished to the receiving district and is to certify that the material supplied is the same composition as originally qualified. This material also requires field approval in accordance with Sec 1059.40.4.
1059.2.3 Sampling of Protective Coating for Concrete Bents and Piers (urethane), Protective Coating for Concrete Bents and Piers (epoxy), Concrete and Masonry Protective Systems, Sacrificial Graffiti Protection Systems and Temporary Coating for Concrete Bents and Piers (weathering steel)
Take samples any time the certification indicates test results approaching the specification limits or any time that conditions warrant additional inspection. When samples are taken, the sample size is 1 qt. (1 liter) in a screw top can. Use AASHTOWARE Project (AWP) and include complete information as to brand name and lot or batch number. The manufacturer's certification for the lot sampled is retained in the district office.
1059.3 Report
If the material is accepted in the field, it is reported through AWP. The form should show all pertinent information regarding the material and the certification is retained in the district office. The report is to indicate acceptance, qualified acceptance, or rejection. Appropriate remarks, as described in EPG 106.20 Reporting, are to be included in the report to clarify conditions of acceptance or rejection.
Articles in "1059 Protective Coating Material"
This category contains only the following page.