751.21.1 Reinforcement
751.21.1.1 Single Column Design
Top Slab Modifications at Intermediate Bent:
The reinforcement shown below shall be used in place of the design slab steel.
(1) designed slab steel
(SINGLE COLUMN)
751.21.1.2 Web Reinforcement
Top Slab Modifications at Intermediate Bent:
751.21.2 Miscellaneous Details
751.21.2.1 Access Doors
ACCESS DOORS (RECTANGLE)
WEIGHT 179#
ACCESS DOORS (OVAL)
See Section 4A for painting or galvanizing note.
ACCESS DOORS LOCATION
- Generally, access doors shall be positioned on or near 1/4 point of span and centerline of roadway.
It is permissible to shift position of access doors when:
- Girder is located at centerline of bridge
- To prevent cutting additional slab bars
- To clear construction joints
- To maintain adequate vertical clearance
If possible, do not locate access doors over a roadway or berm.
PLAN OF ACCESS DOOR SHOWING REINFORCEMENT |