Category:1002 Aggregate for Asphaltic Concrete: Difference between revisions
No edit summary |
No edit summary |
||
Line 163: | Line 163: | ||
|} | |} | ||
[[Category: 1000 Materials]] | [[Category: 1000 Materials|1002]] |
Revision as of 08:04, 13 July 2007
This guidance establishes procedures for the inspection and acceptance of coarse aggregate, fine aggregate, hydrated lime, and mineral filler for use in asphaltic concrete.
1002.1 Procedure
Inspection, testing, and sampling will be governed by the instructions contained in General Requirements for Material.
Field tests required are as follows:
TEST | Template | Template Description |
---|---|---|
Sieve Analysis | T27 | Sieve Analysis of Fine and Coarse Aggregate |
Percent Deleterious | SAA001Ax* | NEWEST Deleterious 1002 C Aggregate |
Lightweight particle content, including coal and lignite, in fine aggregate | SAA001Ix* | NEWEST Deleterious 1002 F Aggregate |
Plastic Index | SAA008Ax* | NEWEST Aggregate Plasticity Index |
Consensus Tests | SAA027Ax* | NEWEST Consensus Properties |
*Test Template numbers have been depicted with a generic ‘x’ as some templates are updated and the last letter in the template name may change. The most current template for a template sequence should contain ‘NEWEST’ at the beginning of the template name. |
Samples required for Laboratory tests are as follows:
- (a) Initial Evaluation for coarse aggregate.
- (b) Source Approval.
- (c) Trial Mix samples.
1002.2 Acceptance
Source Approval is to be based on the results of Laboratory tests. Acceptance is based on routine tests in the field to ensure compliance with Sec 1002.
1002.2.1 Acceptance or rejection of aggregates for asphaltic concrete will be on the basis of quality and the gradation requirements of Standard Specification Sections 1002.2 and 1002.3 in Sec 1002, placing full responsibility for obtaining the proper gradation shown on the approved job mix formula on the contractor. It is expected, however, that the District Construction and Materials Engineer will cooperate with the contractor by keeping him informed as to whether the produced material can be combined to meet the gradation shown in the approved job mix formula.
1002.2.2 If the contractor desires to have material produced to comply with gradations that he has selected as being more applicable to the approved job mix, he shall furnish the necessary gradation requirements to the District Construction and Materials Engineer and the aggregate producer in writing. The inspector should then immediately notify both the contractor and the producer when the material, as produced, approaches or exceeds these additional limits. This procedure should be explained to all contractors so that they may proceed on that basis, if they prefer. Where contractors are not willing to furnish adequate and definite instructions, the basis of acceptance or rejection of the material will be as described in paragraph 1002.2.1 above.
1002.3 Records and Reports
All plant records shown in General Requirements for Material - Records and Reports shall be maintained. The aggregate shall be reported through SiteManager in accordance with Automation Section AS-3510. In addition, sieve analysis should be furnished to the contractor on Impromptu report T707.imr or T707ave2.imr as the aggregate is produced.
1002.4 Qualified Mineral Filler for Stone Matrix Asphalt (SMA)
Note: Being listed here is not a requirement of acceptance. Other suppliers not listed here may still meet the Specification and be accepted. | ||
Product Name* | Supplier | |
---|---|---|
Mineral Filler | Mississippi Lime Co | |
#2 Quarry Ste. Genevieve | ||
P.O. Drawer 31 | ||
Ste. Genevieve, MO 63670 | ||
Mineral Filler | Springfield Plant (Ash Grove) | |
P.O. Box 323 | ||
Route 3 | ||
Springfield, MO 65804 | ||
Mineral Filler | Carthage Crushed Limestone | |
P.O. Box 718 | ||
Carthage, MO 64836 | ||
Mineral Filler | J. M. Huber | |
P.O. Box 4005 | ||
3150 Gardner Expressway | ||
Quincy, IL 62301 | ||
Mineral Filler | Kerford Limestone Co. | |
P.O. Box 449 | ||
Weeping Water, NE 68463 | ||
Mineral Filler | Omya Quincy, Inc. (Quincy Carbonate) | |
P.O. Box 3563 | ||
Quincy, IL 62301-3563 | ||
Fly Ash | City Utilities, Springfield, James River | |
Springfield, MO 64132 | ||
Fly Ash | City Utilities, Springfield, Southwest Plant | |
Springfield, MO 65807 | ||
Fly Ash | Grand River Dam Authority (GRDA) | |
Chouteau, OK | ||
Fly Ash | Headwaters, Cincinnati (Thomas Hill) | |
2303 Gilbert Ave | ||
Cincinnati, OH 45206 | ||
Fly Ash | Headwaters Resources | |
P.O. Box 297 | ||
555 Point Ferry Road | ||
Newark, AR 72562 | ||
Fly Ash | Headwaters Resources | |
Sikeston Power Station | ||
1551 West Wakefield Street | ||
Sikeston, MO 63801 | ||
Fly Ash | Headwaters Resources | |
James River Power Station | ||
Springfield, MO | ||
Fly Ash | Lafarge North America | |
Nearman Creek Power Station | ||
Kansas City, KS | ||
Fly Ash | Lafarge North America | |
Iatan Power Station | ||
Iatan, MO | ||
Fly Ash | Lafarge North America | |
LaCygne Power Station | ||
LaCygen, KS | ||
Fly Ash | Mineral Solutions (Montrose) | |
Ladue, MO | ||
Fly Ash | Mineral Resources Tech | |
(Ameren - Meramec Station) | ||
1608 Rosewall Drive | ||
St. Charles, MO | ||
* Mineral Filler = ground limestone |