1033.4 Laboratory Testing Guidelines for Sec 1033: Difference between revisions
m updated link |
m Per CM, revision reflects AASHTO's renaming of test method T23 to R100 |
||
(One intermediate revision by the same user not shown) | |||
Line 4: | Line 4: | ||
Tests consist of compression and absorption. | Tests consist of compression and absorption. | ||
'''Compression Test.''' Samples may consist of two standard concrete cylinders made in accordance with AASHTO | '''Compression Test.''' Samples may consist of two standard concrete cylinders made in accordance with AASHTO R100 or one core drilled from the wall of the section in accordance with AASHTO T280. | ||
'''Absorption Test.''' Samples shall be tested in accordance with AASHTO T280. Test results and calculations shall be recorded through | '''Absorption Test.''' Samples shall be tested in accordance with AASHTO T280. Test results and calculations shall be recorded through AASHTOWARE Project (AWP). | ||
==1033.4.2 Sample Record== | ==1033.4.2 Sample Record== | ||
All sample records shall be completed in | All sample records shall be completed in AASHTOWARE Project (AWP), as described in [[:Category:101 Standard Forms#Sample Record, General|AWP MA Sample Record, General]]. Test results shall be reported on the appropriate templates under the Tests tab. Compression test results for concrete cylinders shall include the notation in remarks, "Specimens submitted for compressive strength at the age indicated." Compression test results for concrete cores shall include the notation in remarks, "Sample submitted for the determinations indicated." Absorption test results for concrete cores or pieces from the wall of the section shall indicate acceptance, qualified acceptance, or rejection. Appropriate remarks, as described in [[106.20 Reporting|EPG 106.20 Reporting]], are to be included in the remarks to clarify conditions of acceptance or rejection. | ||
[[Category:1033 Precast Drainage Units]] | [[Category:1033 Precast Drainage Units]] |
Latest revision as of 15:13, 9 November 2021
This article establishes procedures for Laboratory testing and reporting samples of precast reinforced concrete manhole and drop inlet sections. Refer to Sec 1033 for MoDOT's specifications.
1033.4.1 Procedure
Tests consist of compression and absorption.
Compression Test. Samples may consist of two standard concrete cylinders made in accordance with AASHTO R100 or one core drilled from the wall of the section in accordance with AASHTO T280.
Absorption Test. Samples shall be tested in accordance with AASHTO T280. Test results and calculations shall be recorded through AASHTOWARE Project (AWP).
1033.4.2 Sample Record
All sample records shall be completed in AASHTOWARE Project (AWP), as described in AWP MA Sample Record, General. Test results shall be reported on the appropriate templates under the Tests tab. Compression test results for concrete cylinders shall include the notation in remarks, "Specimens submitted for compressive strength at the age indicated." Compression test results for concrete cores shall include the notation in remarks, "Sample submitted for the determinations indicated." Absorption test results for concrete cores or pieces from the wall of the section shall indicate acceptance, qualified acceptance, or rejection. Appropriate remarks, as described in EPG 106.20 Reporting, are to be included in the remarks to clarify conditions of acceptance or rejection.