(4 intermediate revisions by one other user not shown) |
Line 1: |
Line 1: |
| {|style="padding: 0.3em; margin-left:15px; border:1px solid #a9a9a9; text-align:center; font-size: 95%; background:#f5f5f5" width="160px" align="right"
| | ==Maintenance Planning Guideline== |
| |-
| | See [[:Category:170 Maintenance Activity Planning Guidelines#R319 Pipe Culvert Repairs (LF)|Maintenance Planning Guide for Installing Pipe Liners]]. |
| |'''Code:''' R319
| |
| |} | |
| '''Definition'''
| |
|
| |
|
| The time and expenses incurred from removing and replacing pipe culverts. Includes time and expenses incurred for installing a new lining in an existing culvert.
| | Index of all [[:Category:170 Maintenance Activity Planning Guidelines#Index of Printable Planning Guides|Maintenance Planning Guidelines]]. |
| | |
| '''Purpose'''
| |
| | |
| To install new pipe liners in existing pipe culverts.
| |
| | |
| '''Scheduling'''
| |
| | |
| As needed year around.
| |
| | |
| '''Recommended Equipment'''
| |
| | |
| *Trucks
| |
| *Backhoe
| |
| *Loader
| |
| *Mudjack or Concrete Mixer
| |
| *Traffic Control Equipment see [[616.23 Traffic Control for Field Operations|Traffic Control for Field Operations]]
| |
| | |
| '''Recommended Material'''
| |
| | |
| *Pipe Liner
| |
| *Slurry Mix
| |
| *Portland Cement
| |
| *Agricultural Lime
| |
| *Water
| |
| | |
| '''Recommended Procedure'''
| |
| | |
| 1. Consult district Design on size and placement of pipe liner.
| |
| | |
| 2. Call Dig Rite and MoDOT to check for utilities.
| |
| | |
| 3. Place traffic control devices as needed.
| |
| | |
| 4. Clean out ditch, if necessary, to make room for liner.
| |
| | |
| 5. Insert liner.
| |
| | |
| 6. Form upstream and downstream ends and mudjack between liner and existing pipe.
| |
| | |
| 7. Grade and reshape shoulder, as necessary.
| |
| | |
| 8. Seed and mulch, as necessary
| |
| | |
| 9. Clean work area.
| |
| | |
| 10. Remove traffic control devices.
| |
| | |
| '''Safety'''
| |
| | |
| Call before you dig to locate utilities '''(1-800-DIG-RITE)'''. Watch out for "pinch points." Wear all appropriate PPE. Reference the [http://lnapp1/RI/RIManual.NSF/SHToC?OpenView Safety Policies, Rules & Regulations-Employee Handbook.]
| |
| | |
| '''Other Considerations'''
| |
| | |
| Use appropriate size liner for application. Follow manufacture’s instructions on installation.
| |
| | |
| '''References'''
| |
| | |
| [http://modot.mo.gov/business/standards_and_specs/Sec0735.pdf Standard Specifications Sec 735]
| |
| | |
| {|
| |
| |[[Image:735 Pipe Liner1.jpg|400px]] || [[Image:735 Pipe Liner2.jpg|400px]]
| |
| |-
| |
| |text align="center"|'''Rusted Out Pipe Invert''' || text align="center"|'''Pipe Liner Installation'''
| |
| |-
| |
| |[[Image:735 Pipe Liner3.jpg|400px]] || [[Image:735 Pipe Liner4.jpg|400px]]
| |
| |-
| |
| |text align="center"|'''Pipe Liner Installation''' || text align="center"|'''Pipe Liner Installation'''
| |
| |-
| |
| |[[Image:735 Pipe Liner5.jpg|400px]] || [[Image:735 Pipe Liner6.jpg|400px]]
| |
| |-
| |
| |text align="center"|'''Pipe Liner Installation''' || text align="center"|'''Pipe Liner Installation '''
| |
| |-
| |
| |[[Image:735 Pipe Liner7.jpg|400px]] || [[Image:735 Pipe Liner8.jpg|400px]]
| |
| |-
| |
| |text align="center"|'''Pipe Liner Installation''' || text align="center"|'''Pipe Liner Installation'''
| |
| |-
| |
| |[[Image:735 Pipe Liner9.jpg|400px]] || [[Image:735 Pipe Liner10.jpg|400px]]
| |
| |-
| |
| |text align="center"|'''Pipe Liner Installation''' || text align="center"|'''Grouting Pipe Liner to Culvert End'''
| |
| |-
| |
| |[[Image:735 Pipe Liner11.jpg|400px]] || [[Image:735 Pipe Liner12.jpg|400px]]
| |
| |-
| |
| |text align="center"|'''Grouted Pipe Liner''' || text align="center"|'''Finished Product'''
| |
| |}
| |