Category:1130 Traffic Signal Lamps: Difference between revisions
info from material manual |
m Per CM, removed archaic SiteManager info and replaced with AASHTOWARE info |
||
(7 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
{|style="padding: 0.3em; margin-left:1px; border:2px solid #a9a9a9; text-align:center; font-size: 95%; background:#f5f5f5" width="280px" align="right" | |||
|- | |||
|'''MGS Information''' | |||
|- | |||
|[https://www.modot.org/general-services-specifications-mgs-subject Current General Services Specifications (MGS) By Subject] | |||
|} | |||
This article establishes procedures for inspecting and sampling traffic signal lamps purchased to comply with the bid request issued by MoDOT. | This article establishes procedures for inspecting and sampling traffic signal lamps purchased to comply with the bid request issued by MoDOT. | ||
Line 9: | Line 16: | ||
===1130.2.1 Testing=== | ===1130.2.1 Testing=== | ||
Samples shall be subjected to a Laboratory visual examination to determine compliance for light center length, markings, position of burning, bulb type, base type, and filament type. Manufacturer's certifications shall be checked for compliance with all requirements of the bid request. Data on Laboratory findings shall be recorded in Laboratory workbooks. This information shall then be recorded through | Samples shall be subjected to a Laboratory visual examination to determine compliance for light center length, markings, position of burning, bulb type, base type, and filament type. Manufacturer's certifications shall be checked for compliance with all requirements of the bid request. Data on Laboratory findings shall be recorded in Laboratory workbooks. This information shall then be recorded through AASHTOWARE Project (AWP). | ||
===1130.2.2 Sample Record=== | ===1130.2.2 Sample Record=== | ||
The sample record shall be completed in | The sample record shall be completed in AASHTOWARE Project (AWP) in accordance with [[:Category:101 Standard Forms #Sample Record, General|AWP MA Sample Record, General]], and shall indicate acceptance, qualified acceptance, or rejection. Appropriate remarks, as described in [[106.20 Reporting|EPG 106.20 Reporting]], are to be included in the remarks to clarify conditions of acceptance or rejection. Test results shall be reported on the appropriate templates under the Tests tab. |
Latest revision as of 07:10, 17 September 2021
MGS Information |
Current General Services Specifications (MGS) By Subject |
This article establishes procedures for inspecting and sampling traffic signal lamps purchased to comply with the bid request issued by MoDOT.
1130.1 Procedure
Refer to Signal Bulb Inspection Process.
1130.2 Laboratory Testing Guidelines
This article establishes procedures for sampling, testing and reporting traffic signal lamps purchased to comply with the bid request issued by MoDOT.
1130.2.1 Testing
Samples shall be subjected to a Laboratory visual examination to determine compliance for light center length, markings, position of burning, bulb type, base type, and filament type. Manufacturer's certifications shall be checked for compliance with all requirements of the bid request. Data on Laboratory findings shall be recorded in Laboratory workbooks. This information shall then be recorded through AASHTOWARE Project (AWP).
1130.2.2 Sample Record
The sample record shall be completed in AASHTOWARE Project (AWP) in accordance with AWP MA Sample Record, General, and shall indicate acceptance, qualified acceptance, or rejection. Appropriate remarks, as described in EPG 106.20 Reporting, are to be included in the remarks to clarify conditions of acceptance or rejection. Test results shall be reported on the appropriate templates under the Tests tab.