1044.5 Laboratory Testing Guidelines for Sec 1044: Difference between revisions
m →1044.5.2 Sample Record: Per CM, updated link |
m →1044.5.2 Sample Record: Per CM, replaced archaic "Automation Section" with AWP MA Sample Record, General |
||
(2 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
This article establishes procedures for Laboratory testing and reporting galvanized steel | This article establishes procedures for Laboratory testing and reporting galvanized steel | ||
posts. Refer to [http://www.modot. | posts. Refer to [http://www.modot.org/business/standards_and_specs/SpecbookEPG.pdf#page=14 Sec 1044] for MoDOT’s specifications. | ||
==1044.5.1 Procedure== | ==1044.5.1 Procedure== | ||
Laboratory tests to be performed on the sample are designated by the inspector in the remarks area of | Laboratory tests to be performed on the sample are designated by the inspector in the remarks area of AASHTOWARE Project (AWP). | ||
===1044.5.1.1 Chemical Tests=== | ===1044.5.1.1 Chemical Tests=== | ||
The procedure for determining mass of coating shall be according to AASHTO T65. Original test data and calculations shall be recorded in Laboratory workbooks. Test results shall then be recorded through | The procedure for determining mass of coating shall be according to AASHTO T65. Original test data and calculations shall be recorded in Laboratory workbooks. Test results shall then be recorded through AWP. | ||
===1044.5.1.2 Physical Tests=== | ===1044.5.1.2 Physical Tests=== | ||
Dimensions, shape, mass, length, and hole punching shall be measured for conformance to [http://www.modot.mo.gov/business/standards_and_specs/documents/90303.pdf Standard Plan 903.03]. To determine the mass per linear foot (linear meter) of a galvanized steel post after fabrication, refer to [[:Category:1044 Posts for Markers and Delineators#1044.3 Calculations|1044.3 Calculations]]. Test results shall be recorded through | Dimensions, shape, mass, length, and hole punching shall be measured for conformance to [http://www.modot.mo.gov/business/standards_and_specs/documents/90303.pdf Standard Plan 903.03]. To determine the mass per linear foot (linear meter) of a galvanized steel post after fabrication, refer to [[:Category:1044 Posts for Markers and Delineators#1044.3 Calculations|1044.3 Calculations]]. Test results shall be recorded through AWP. | ||
==1044.5.2 Sample Record== | ==1044.5.2 Sample Record== | ||
The sample record shall be completed in | The sample record shall be completed in AWP, as described in [https://epg.modot.org/forms/CM/AWP_MA_Sample_Record_General.docx AWP MA Sample Record, General], and shall indicate acceptance, qualified acceptance, or rejection. Appropriate remarks, as described in [[106.20 Reporting|EPG 106.20 Reporting]], are to be included in the remarks to clarify conditions of acceptance or rejection. Test results shall be reported on the appropriate templates under the Tests tab. | ||
[[Category:1044 Posts for Markers and Delineators]] | [[Category:1044 Posts for Markers and Delineators]] |
Latest revision as of 07:53, 24 November 2021
This article establishes procedures for Laboratory testing and reporting galvanized steel posts. Refer to Sec 1044 for MoDOT’s specifications.
1044.5.1 Procedure
Laboratory tests to be performed on the sample are designated by the inspector in the remarks area of AASHTOWARE Project (AWP).
1044.5.1.1 Chemical Tests
The procedure for determining mass of coating shall be according to AASHTO T65. Original test data and calculations shall be recorded in Laboratory workbooks. Test results shall then be recorded through AWP.
1044.5.1.2 Physical Tests
Dimensions, shape, mass, length, and hole punching shall be measured for conformance to Standard Plan 903.03. To determine the mass per linear foot (linear meter) of a galvanized steel post after fabrication, refer to 1044.3 Calculations. Test results shall be recorded through AWP.
1044.5.2 Sample Record
The sample record shall be completed in AWP, as described in AWP MA Sample Record, General, and shall indicate acceptance, qualified acceptance, or rejection. Appropriate remarks, as described in EPG 106.20 Reporting, are to be included in the remarks to clarify conditions of acceptance or rejection. Test results shall be reported on the appropriate templates under the Tests tab.