Category:1140 Polyethylene Bags: Difference between revisions
m article construction |
m updated link |
||
(3 intermediate revisions by the same user not shown) | |||
Line 3: | Line 3: | ||
|'''MGS Information''' | |'''MGS Information''' | ||
|- | |- | ||
|[ | |[https://www.modot.org/general-services-specifications-mgs-subject Current General Services Specifications (MGS) By Subject] | ||
|} | |} | ||
Line 15: | Line 15: | ||
===1140.1.2 Samples=== | ===1140.1.2 Samples=== | ||
One bag of each size represented by the purchase order is to be submitted to the Central Laboratory. Bags are to be selected from random rolls/packages and at random locations therein. The first bag on a roll/package is not to be sampled. [[ | One bag of each size represented by the purchase order is to be submitted to the Central Laboratory. Bags are to be selected from random rolls/packages and at random locations therein. The first bag on a roll/package is not to be sampled. A sample record as directed in [[106.3 Samples, Tests and Cited Specifications#106.3.1.2 Submission of Laboratory Samples|EPG 106.3.1.2 Submission of Laboratory Samples]] is to be produced for each sample and is to include all pertinent information, including field inspection results. If the sample fails to meet the requirements of the specifications, 2 additional bags, each from different rolls/packages and different locations therein, are to be submitted for testing. Both of the resamples must meet the specifications or the entire shipment will be rejected. | ||
==1140.2 Report== | ==1140.2 Report== | ||
The laboratory will complete and issue the test reports. | The laboratory will complete and issue the test reports. |
Latest revision as of 07:28, 16 October 2018
MGS Information |
Current General Services Specifications (MGS) By Subject |
This article establishes procedures for inspecting, acceptance and reporting polyethylene bags for various uses.
1140.1 Procedure
1140.1.1 Inspection
Bags are to be randomly inspected at destination for visual and dimensional compliance prior to sampling.
1140.1.2 Samples
One bag of each size represented by the purchase order is to be submitted to the Central Laboratory. Bags are to be selected from random rolls/packages and at random locations therein. The first bag on a roll/package is not to be sampled. A sample record as directed in EPG 106.3.1.2 Submission of Laboratory Samples is to be produced for each sample and is to include all pertinent information, including field inspection results. If the sample fails to meet the requirements of the specifications, 2 additional bags, each from different rolls/packages and different locations therein, are to be submitted for testing. Both of the resamples must meet the specifications or the entire shipment will be rejected.
1140.2 Report
The laboratory will complete and issue the test reports.